CALYS 50 ON-SITE MULTIFUNCTION CALIBRATOR 

   Calys 50 is a portable calibrator able to measure and to generate simultaneously on 2 isolated channels.

   Calys 50 is used to measure and generate voltage, current, frequency, resistance signals and also resistive probes and thermocouples.

 

 

 

  Range direct current : 50 mA /accuracy 0,018%

  Range DC current : 24 mA /accuracy 0,018%

  Range direct voltage : 0-100 mV /accuracy 0,013%

  Range frequency and counting : 20 kHz /accuracy 0,005%

  Range frequency and pulses : 0-1000 Hz /accuracy 0,005%

  Range resistance : 0-4000 Ohm /accuracy 0,012%

  Temperature range : 0-1200°C /accuracy 0,012%

  Waterproof : IP54

  Operating conditions : 0-50°C; 10-80% RH

  Screen size : 210 x 110 x 50 mm

  Weight : 0,9 kg

Description Calys 50 allows the following physical values to be measured and simulated voltage, current, resistance, temperature by resistive probes and thermocouples, frequency for frequency signals and for dry contacts. It is able to perform scaling of process signals and so to correct temperature probes. It is compatible with HART transmitters by inserting a 250 ohms resistance which doesn’t disturb digital data transfer.

Dual display indicates permanently the measurement value, and also the emitted value, the gauge and the used functions. On the top date, time and also external temperature are also indicated. During measuring average, maximum, minimum and the number of measurements are displayed on the left. While for emission this part of screen displays all details of ramps, steps and constant value emission functions. Drop-down menus are used with the navigator, and an on-line help is available to make easier connections of probes and wires.

Display resolution  Calys 50 allows the digit number after the dot to be selected. This function is justified by the needs of users who want or not to display the best resolution for calibration or on the contrary limit it for simple verifications.

"Easy connect" system  This unique system is used by pushing on the terminal’s top, by inserting:

- Wires with a diameter up to 3 mm,

- Compensated thermocouple connectors,

- Pin terminal on front panel, and next by releasing.

Wires are tighten between 2 brass plates which provide an great thermal gradient, so that allows a very good cold junction compensation for thermocouples. Calys 50 allows 4mm connectors and also security connectors to be connected on the front panel.

 

Memory  Store your calibration procedures in the device and save your results for on site easy and quick calibration during the whole week. Then, upload the data on a computer in order to issue calibration certificates.
Customized calibration certificates  Issue your own customized calibration certificates with DATACAL calibration software (see below).
Additional functions  Scaling, steps, synthetizer, statistical function, etc. make advanced data exploitation easier.

Standard Equipment

- Instrument with a strap and a stand for desktop use, with programmable buttons, screen contrast adjustment and backlight

- Battery (8 hours autonomy in the worst conditions of use)

- Quick battery charger

- 6 testing leads /measuring cables with crocodile clips

- Moulded plastic case

Related products :

Calibrators

- Temperature calibrator

- Thermocouple calibrator

- Volt/ mA calibrator

- Pressure calibrator

- Sound level calibrator

- Humidity calibrator

- EJB 9970 Volt / mA calibrator                NEW   

- EJB 9971 multifunctional thermocouple process calibrator      NEW  

  

 

Bercu nv

Noordschippersdok 13                         T. +32 3 225 32 73                        

B-2060 Antwerp                                  F. +32 3 234 18 49

Belgium                                             ejb@bercu.be

 

www.bercu.be    www.bercu.com    Copyright @ Bercu nv. All rights reserved.