GMI GT-series MULTI-FUNCTION GAS DETECTOR

   Multi-application Gas Detector : PPM, LEL, Volume Methane flammable gas ranges for leak detection with audible and visual "Ticker" (Geiger) indication om ppm range, and loud audible and high visibility alarms for Flammable or Toxic gases.
   Designed for the gas industry, the GT Series are multi-application instruments, satisfying all the needs of service technicians within a single unit.  With 7 modes of operation, the GT Series is the most versatile instrument available for working with gas.

 

 

  Display : digital LCD with backlighting

  LEL : 0-10000 ppm; 0-100%; 0-100% volume gas

  Oxygen (O2) : 0-25%

  Carbon Monoxide (CO) : 0-2000 ppm

  Hydrogen Sulphide (H2S) : 0-100 ppm

  Water Gauge : 0-150 mBar

  Resolution : 1 ppm; 1%; 0,1% vol.; 1 mBar

  Alarm : 80 dB Audible; highly visible flashing LEDs

  Pump : integral with pressure sensor for flow fail detection

  Operating temperature : -20 to +50°C

  Humidity : 0 to 95% RH, non-condensing

  ATEX, UL, CSA, IEC Ex, IP54

  Power/battery : 3 x approved LR14 alcaline/or rechargeable

  Battery life : 8 hours

  Calibration : automatic

  Dimensions : 290 x 95 x 43 mm

  Weight : 780 g (incl. probe & batteries) 

 

Instruments :
- GT-40 : PPM, LEL, GAS, CO
- GT-41 : PPM, LEL, GAS, O2
- GT-42 : PPM, LEL, GAS, CO, O2
- GT-43 : PPM, LEL, GAS, CO, O2, H2S
- GT-44 : PPM, LEL, GAS

Power/battery
1. 3 x approved LR14 alcaline
2. 3 x approved "C" type rechargeable

Certification 
- UL 913 Class 1, Div Groups C & D  
- SIRA05ATEX Ex II 2G  EEX iad IIB T3
- Class I, Groups C & D
- IECEx Ex iad IIB T3
 

Standard delivery 1  All instruments supplied with User Handbook, Quick Instruction, Calibration Certificate & Configuration Report.  
Standard delivery 2  All instruments supplied in a carrying case with Solid End Probe, Probe Filters, Wrist Strap, Tygon Sample Line, User Handbook, Quick Instruction, Calibration Certificate & Configuration Report.

Accessoires :
- Carrying case
- Hydrophobic Probe Filter
- 35 cm Solid End Probe
- 80 cm s/End (Barhole) Probe
- Steinless Steel (Flue) Probe
- Carbon (Balston) Probe
- Chemical Filter Assembly
- Colour Indicated Silica Gel Bottle
- NOx Absorber Bottle
- Filter Disc - Housing
- Filter Disc - Adaptor
- Tygon Sample Line
- Cotton Filter Assembly
- Auto Calibration station
- Configuration & Field Calibration CD
- Set-up Software
- USB serial adaptor
 

Bercu nv

Noordschippersdok 13                         T. +32 3 225 32 73                        

B-2060 Antwerp                                  F. +32 3 234 18 49

Belgium                                             ejb@bercu.be

 